Interface loading
The concept of interface loading allows for the application of a facial
distributed pressure on an arbitrary part of the body's external surface. This
part does not have to coincide with external faces of the body's volumetric
mesh. In order to apply the interface loading the user has to:
- Mesh the part of the body's external surface to be loaded using shell elements (S3,
S4, S6 or S8). The order of the nodes should be clockwise when looking
towards the body, i.e. the normal to the shell should point into the body.
- Declare that the sole purpose of these elements is to apply facial
loading by specifying the parameter DLOAD on the
*ELEMENT card used to define these shells.
- Apply a pressure to these shell elements using the label 'I' (for
Interface) instead of the label 'P' (which is the conventional label for
pressure loading on faces) on a *DLOAD card. The pressure loading acts in the direction of
the normal to the shell elements. The normal on a shell element is such,
that while looking in the direction of the normal the node numbering is
clockwise.